Hyundai Tucson: Condensor - Inspection
WARNING
Before measuring the pressure of the refriferant line, check whether the refrigerant amount is charged in accordance with the specified charging amount.
(Refer to Heating, Ventilation, Air Conditioning - "Specifications")
- Turn the ignition switch OFF.
- Install the refrigerant recovery /recycling/charging system.
(Refer to Air Conditioning System - "Repair procedures")
- Turn ON the ignition switch, put into operation the air conditioner.
- Calculate the reference voltage of the Recovery/Recycle/Recharge machine high pressure value using the formula below.
Reference voltage (V) = 0.0088 * pressure(psi) + 0.37
- Measure the sensor output voltage between terminal "1" and "2".
- If the reference voltage value and the sensor output voltage value are close to each other, the air conditioner pressure transducer is normal.
- If OV is output or the reference voltage value and sensor output voltage value are not close to each other, replace the air conditioner pressure transducer.
WARNING
Check if the output voltage changes when the high pressure value of
the refrigerant line changes.
Replacement
- Disconnect the negative (-) battery terminal.
- Recover the refrigerant with a recovery/charging station.
(Refer to Air conditioning System - "Repair procedures")
- Disconnect the A/C pressure transducer connector (A).
- Remove the A/C pressure transducer (A).
Tightening torque : 9.8 - 11.8 N.m (1.0 - 1.2 kgf.m, 7.2 - 8.7 lb-ft)
- Install in the reverse order of removal.
WARNING
When installing, replace it with a new O-ring.
Description
The evaporator temperature sensor will detect the evaporator core temperature and interrupt compressor relay power in order to prevent evaporator from freezing by excessive cooling.
Inspection
- Turn the ignition switch ON.
- Turn the A/C swicth ON.
- Measure resistance between terminal "+" and "-" of the evaporator temperature sensor.
Replacement
- Disconnect the negative (-) battery terminal.
- Remove the evaporator core.
(Refer to Heater - "Evaporator Core")
- Separate the evaporator temperature sensor (A) from the evaporator core.
- Install in the reverse order of removal.
Description
The In-car air temperature sensor is built in the heater & A/C control unit.
The sensor consists of a thermistor that measures the inside temperature. The signal decided by the resistance value that changes in accordance with perceived inside temperature, is delivered to heater control unit, and according to this signal, the control unit regulates in-car temperature to intended value.
READ NEXT:
In-car sensor
Components Location
In-car sensor
Replacement
Disconnect the negative (-) battery terminal.
Remove the crash pad center panel.
(Refer to Body (Interior and Exterior) - "Crash Pad Center Panel")
Using a screwdriver or re
PM sensor
Components Location
PM sensor
Replacement
Disconnect the negative (-) battery terminal.
Remove the crash pad lower panel.
(Refer to Body (Interior and Exterior) - "Crash Pad Lower Panel")
Loosen the mounting screw, remove
SEE MORE:
Heater - Replacement
Disconnect the negative (-) battery terminal.
Recover the refrigerant with a recovery/recycling/charging station.
(Refer to Air conditioning System - "Repari procedures")
When the engine is cool, drain the engine coolant from the r
Hood
Opening the hood
Park the vehicle and set the parking
brake.
Pull the release lever to unlatch the
hood. The hood should pop open
slightly.
Go to the front of the vehicle, raise the
hood slightly, push up the secondary
l
Information
- Home
- Hyundai Tucson - Fourth generation (NX4) - (2020-2023) - Owner's Manual
- Hyundai Tucson - Fourth generation (NX4) - (2020-2023) - Workshop Manual